Designed to prevent passage of fire through concealed voids within the external fabric of a masonry wall construction, but more specifically where the junction is formed between the external cavity and the party wall cavity.
Designed for installation within masonry cavities at the junction with the external cavity and party wall cavity. Accommodates a maximum void of 175mm. Easy installation process. Installed under compression. For voids up to 150mm a minimum compression of 15mm is required, thereafter 20mm compression is required up to the maximum void of 175mm. Tested and assessed to the basic principles of BS 476 Part 20: 1987. Suitable for vertical orientation. Provides up to 120 minutes fire resistance
This download is for the Masonry Party Wall Cavity Stop Sock 552 Range of cavity barriers by Mayplas.
Read moreWe have more variations, please download the object to get them all.