Designed to prevent passage of fire through concealed voids within the external fabric of a masonry wall construction.
Designed for installation within masonry cavities. Accommodates a maximum void of 175mm. Easy installation process. Installed under compression. For voids up to 150mm a minimum compression of 15mm is required, thereafter 20mm compression is required up to the maximum void of 175mm. Tested and assessed to the basic principles of BS 476 Part 20: 1987. Suitable for both vertical and horizontal orientation. Solutions available offering either 60 minutes or 120 minutes fire resistance performance
This download is for the Masonry Cavity Stop Sock 552 Range of cavity barriers by Mayplas.
Read moreWe have more variations, please download the object to get them all.